Performance Analysis of Double Coil Wire Inserts for Heat Transfer in a Circular Tube
Keywords:
Enhancement efficiency, heat transfer, Double coil wire inserts, High/ low density, pressure dropAbstract
Abstract
This work represents the experimental investigation results for turbulent flow heat transfer in a horizontal pipe by using double coil wire inserts and air as working fluid, experiments were carried out for a tube with and without double coil wire inserts at constant heat supply and different mass flow. The double coil wire insert are four different pitch of 12, 14, 16 and 18 mm and three different wire diameter of 1.6, 2 and 2.6 mm for outer coil and 0.9, 1.2 and 1.5 mm for inner coil wire diameter with 25 mm outer coil and 11 mm inner coil diameter. The Reynolds number varied from 4000 to 7242. Both heat transfer coefficient and pressure drop are calculated and the results are compared with those of bare tube. It was found that the enhancement of heat transfer with double coil wire inserts as compared to plain tube varied from 3 to 46% for various inserts. Also the results are compared with the plane tube without insert.
Keywords: Enhancement efficiency, heat transfer, Double coil wire inserts, High/low density, pressure drop
Cite this Article
Pathan Abdul Hai Khan, Sandip Kale. Performance analysis of double coil wire inserts for heat transfer in a circular tube. Journal of Refrigeration, Air conditioning, Heating and Ventilation. 2015; 2(3): 25–33p.
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |