An Exergetic based Assessment of Biogas as an Energy Source in a Hybrid Refrigeration System
Abstract
The analysis of biogas operated Ammonia-Water vapor compression absorption (hybrid) refrigeration system was carried out based on computational model being developed and the thermodynamic properties of working fluids have been used from the computer code. The variation of performance parameters such as exergy loss, COPCOOLING, COPHEATING and Exergy efficiency are studied with varying generator temperature, evaporator temperature, condenser and absorber temperature. The results indicate that maximum COP cooling as well COP heating value are found to be at generator temperature of 80 oC for the same variation in the generator temperature from 80 oC
–135 oC. The effect of the varying cooling capacity on the exergy loss in different components as well as exergy efficiency is also studied in the analysis of the hybrid system which revealed the maximum exergy loss is found in the generator which goes on increasing with an increase in the cooling capacity of the system.
Keywords: Biogas, Boiler, Hybrid system, Compressor, COP, Exergy
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |